Rounded Balloon
image/svg+xml
+ Dir.
Description
6.3±0.3
- Dir.
± Tol.
Product: Conduit support bracketProblem: The conduit is not suppose to contact the ceilingObjective: Determine the min. & max. assembly height
Date: 1/23/16Units: mmAuthor: E. Sierra
6
2.0
40
1.5
1.3
1.3
20
1.0
66
7.1
0
Totals
Assy. shiftPart 3
40±1.5
6±2
20±1
Assy. shiftPart 2
max-mindistance
Part 1
Part 2
Part 3
Part 1 to edge of part 2
Part 2 edge to fastener assy.
Part 2 & bolt clearance (shift)
Bolt clearance (shift) & Part 3
Part 3 fastener assy. to Part 3 edge
Dimension and Tolerance: 66 ± 7.1
Maximum Distance: 73.1Minimum Distance: 58.9
M4 bolt
Assembly shift tolerance calculation[6.3+0.3-4.0]/2 = [2.6]/2 = ±1.3
CALIPER ENGINEERING
+Dir.
-Dir.
66=(66-0)